Weltouch | Cy-210b Manual

: Establish the duration that the mechanical electrodes remain clamped post-current to allow the nugget to solidify.

Maintains a stable current throughout the welding process to compensate for changes in secondary resistance. Program Cycles:

, proper wiring of foot switches is critical for safe operation: Single-Level Foot Switch:

For a device without a screen, its ability to convey information relies entirely on visual and output signals. Here is the breakdown of its informative features: weltouch cy-210b manual

: A 100g calibration weight (or 200g – confirm your model’s required weight). Do not use coins; their mass varies.

Mount the external around the secondary welding copper busbar. Ensure the coil does not touch nearby ferromagnetic metals.

Connect the remaining single wire from Level 1 to to control the "Start 1" schedule initiation. : Establish the duration that the mechanical electrodes

Connect the shielded toroidal output cable to the dedicated sensor inputs on the rear terminal strip of the CY-210B to read accurate RMS current data.

Define a high/low limit window percentage (from 0% up to 49%).

Examines each half-cycle of actual weld current and compensates for fluctuations to ensure consistent results. Here is the breakdown of its informative features:

The is a highly reliable, microcomputer-controlled constant current AC resistance welding controller. Manufactured by Miyachi (now Amada Weld Tech), this unit stabilizes welding processes by providing real-time secondary constant current feedback.

The CY-210B features self-diagnostics that display error codes for various issues: Current Upper/Lower Limit Error:

is a constant-current AC resistance welding controller. It is designed for precise industrial welding applications, offering advanced monitoring and feedback features to ensure consistent weld quality.