A spare HMI pre-loaded with your latest backup reduces downtime from days to 15 minutes.
: Select the USB drive as the target storage location.
If backing up over Ethernet, ensure your laptop's IP address matches the subnet of the HMI (e.g., HMI is 192.168.1.5 , laptop should be 192.168.1.10 ).
Choose the source as the HMI local hard drive ( HardDisk ) and the destination as your USB drive ( USBDisk ).
This comprehensive guide covers everything you need to know about executing an MCGS HMI backup. You will learn the exact steps, tools, and best practices to safeguard your industrial control data. Understanding MCGS HMI Project Files mcgs hmi backup
The version that is actually running on the HMI hardware. It is compiled and downloaded to the screen (typically .MCE ).
Which (e.g., McgsPro, Embedded Edition) are you using? Are you connecting via USB or Ethernet ?
: Distinguish between the Runtime file (used to run the HMI) and the Source file (editable project). You generally need the Source file for future edits.
A frequent roadblock during an MCGS HMI backup is discovering that the original automation engineer disabled the upload function or password-protected the project to safeguard their proprietary designs. Understanding the Restriction A spare HMI pre-loaded with your latest backup
Knowing how to back up is only half the battle. If a screen fails, you need to know how to load the backup onto a new unit. To restore a project:
Some MCGS panels support an “export to USB” function directly from the running application, provided a “导出到触摸屏” (Export to HMI) button has been configured by the original programmer:
Ensure your PC is on the same local area network (LAN) as the HMI.
Just as it hit 92%, the factory lights flickered. A transformer outside had hissed its last breath. The HMI screen went black. Elias held his breath, the silence of the stopped machines more deafening than the roar had been. Choose the source as the HMI local hard
For newer MCGS units running on Linux, there are dedicated tools for more comprehensive system maintenance.
Use a consistent naming scheme that includes:
: For on-site maintenance, many MCGS TPC models (such as the 1061Ti series) allow for direct data extraction via a USB drive. By entering the system settings—often accessible by holding the screen during boot-up—operators can navigate to a "System Backup" menu and copy runtime data directly to external storage. Software-Based Uploads
Open the MCGS Embedded Configuration Software on your PC.